Roofing Felt vs Tar Paper a Guide to Underlayment for American Roofs
Roofing projects hinge on the right underlayment. Two terms you’ll hear are roofing felt and tar paper, often used interchangeably in casual conversation. In practice, roofing felt is the broad category, while tar paper refers to an asphalt-saturated felt variant with historical roots in waterproofing. This article clarifies what each term means today, how they’re used in American reroofing, and what homeowners should know when choosing underlayment for durability, safety, and code compliance. The goal is to help readers select the best option for climate, budget, and roof design without sacrificing performance.
Roofing Felt And Tar Paper: Clarifying Terms
Roofing felt is a generic term for a fabric or paper layer saturated with asphalt and used as an underlayment beneath roofing materials. It comes in different base materials, including natural-fiber kraft and fiberglass, and in multiple weight classes. Tar paper is a traditional name for asphalt-saturated felt, sometimes implying heavier tar content or a specific manufacturing process. In modern markets, tar paper is often considered a subset of roofing felt rather than a distinct product. For practical purposes, most homeowners will encounter asphalt-saturated felt marketed as roofing felt, tar paper, or both.
In everyday use, the distinction matters when reading product specs. Roofing felt may be described as “asphalt-saturated felt” or “asphalt-impregnated felt.” Tar paper is frequently described by weight class, such as 15-lb or 30-lb, which refers to the roll’s pounds of material per 100 square feet. The term “felt” is more inclusive and better reflects current U.S. industry terminology, while “tar paper” is a historic or regional label still seen on some catalogs and contractor tags.
What Is Roofing Felt?
Roofing felt is an underlayment used to provide a secondary moisture barrier and to protect the roof deck during construction and weather exposure. It is typically made from a base mat—either natural kraft paper or fiberglass—and coated with asphalt. The coating improves water resistance and helps the material shed moisture until the final roofing layer is installed. Roofing felt acts as a temporary protection and, in some designs, as a long-term underlayment component.
Common weight classes indicate durability and tear resistance. The most widely used weights in residential roofing are 15-lb and 30-lb felt. The weight refers to pounds per 100 square feet (a “square” in roofing terms). Heavier felt (like 30-lb) generally offers greater tear resistance and a longer service life, especially in windy or wet climates. Lighter felt is lighter on an installer’s toolkit and usually cheaper, but it can require more careful handling and quicker replacement if the roof is exposed for extended periods.
Material options have evolved. Traditional felt is either asphalt-saturated kraft paper or fiberglass-treated felt. Some variants add a sanded surface on the outer side to improve grip during installation. There are also newer felt products that incorporate polymer-modified asphalt for enhanced flexibility and moisture resistance. Regardless of the base, felt underlayment remains a cost-conscious choice, especially on simple roof profiles or where climate and code requirements are modest.
What Is Tar Paper?
Tar paper is a historical name for an asphalt-saturated underlayment made from a base mat, typically paper or fiberglass, treated with tar-like bituminous substances. In older constructions, tar paper offered a rudimentary barrier against moisture while shingles were being applied. Today, tar paper is less common as a marketplace label in new construction, largely replaced by modern asphalt-saturated felt and synthetic underlayment products. When you hear tar paper in 2025, it is usually a colloquial reference to asphalt-saturated felt rather than a distinct new product.
Tar paper’s symbolism lies in its tar-centric composition. Some older products or regional references emphasize tar’s waterproofing qualities and pliability in cold weather. Modern equivalents, however, rely on asphalt or synthetic chemistries that outperform older tar-based formulations in durability and environmental exposure. For homeowners purchasing underlayment today, tar paper and roofing felt more often point to the same family of products, with the weight class providing the real specification difference.
Historical Context And Evolution
The concept of a roof underlayment dates back to early shingle roof construction, where builders sought a moisture barrier that could bridge the gap between deck and final roofing. Originally, tar and pitch were used to seal and waterproof, with felt as a carrier material. By the mid-20th century, asphalt-saturated felt became the standard underlayment for many roof types in the United States. This shift offered better waterproofing, easier installation, and compatibility with a wide range of shingles.
As roofing technology progressed, synthetic underlayments emerged in the late 20th and early 21st centuries. These materials use polypropylene or polyester fibers and synthetic bindings, often delivering superior tear strength, water resistance, and UV stability. While traditional felt remains common due to cost and familiarity, many modern roofs deploy synthetic underlayments, especially in regions with extreme weather. Tar paper, once a mainstay, is now largely a historical label for asphalt-saturated felts and is increasingly supplanted by advanced products.
How They Are Used In Modern Roofing
In most contemporary American roof installations, an underlayment layer is placed over the roof deck before shingles or other exterior roofing materials. The underlayment’s primary roles are to provide temporary protection during construction, to add a secondary moisture barrier, and to serve as a cushion to reduce damage to shingles during installation and minor settlement of the deck. Roofing felt, tar paper, and synthetic underlayments all fill this role, but their performance characteristics differ.
Underlayment choice often depends on climate, roof design, and shingles. In milder climates, 15-lb or 30-lb asphalt-saturated felt may suffice when paired with compatible shingles. In regions with heavy snowfall, ice dams, or high winds, builders frequently opt for a higher-strength felt or a synthetic underlayment to bolster resistance to tearing and moisture. Additionally, building codes may require specific underlayment types in certain jurisdictions, particularly near eaves and valleys where water infiltration risk is highest.
Beyond traditional underlayment, many roofs employ specialized layers near the edges and penetrations. An ice and water shield (a self-adhesive, rubberized asphalt membrane) is commonly installed in vulnerable zones such as eaves and around roof penetrations. This membrane provides an extra layer of protection against infiltration from ice dams and wind-driven rain, complementing the main felt or synthetic underlayment.
Material Differences: Felt Vs Tar Paper Vs Synthetic Underlayment
| Aspect | Roofing Felt | Tar Paper | Synthetic Underlayment |
|---|---|---|---|
| Base Material | Asphalt-saturated kraft paper or fiberglass | Asphalt-saturated paper (historical term) | Polypropylene or polyester fabric with synthetic coating |
| Common Weights | 15-lb, 30-lb (per 100 sq ft) | Often referenced similarly by weight (historical) | Measured by thickness/weight (not typically in lb per 100 sq ft) |
| Durability | Good moisture barrier when dry; tear resistance varies by weight | Typically less common in new installs; similar performance to 15-30-lb felt when used historically | High tear resistance; excellent UV stability and walkability |
| Water Resistance | Effective with shingles; becomes less protective if damaged | Historical waterproofing emphasis; reduced performance when torn | Superior water resistance; often sealed at seams |
| Installation | Rolled out and nailed; overlaps specified by manufacturer | Same method in older builds; still used in some regions | Rolled or placed as continuous sheet; often requires specific fasteners or adhesive |
| Climate Suitability | Versatile; weight choice adapts to climate | Historically common in moderate to cool regions | Excellent in harsh climates; favored for extreme weather and modern roofs |
| Cost | Low to moderate; very economical | Similar historical pricing; often replaced by modern felts | Higher upfront cost but longer lifespan and durability |
| Code And Warranty | Widely accepted when installed per code | Depends on region; ensure compatibility with shingles | Commonly required with certain shingle brands; warranty dependent on product |
Performance And Durability
Performance hinges on the material, climate, and installation quality. Roofing felt offers reliable moisture protection when intact and properly overlapped. Heavier weights (like 30-lb) resist tearing better in windy conditions and on steeper slopes. Over time, asphalt can become brittle in cold weather or degrade under prolonged sun exposure, especially on unventilated roofs. Tar paper shares these characteristics, but the exact durability depends on the specific asphalt blend and base material used in the roll.
Synthetic underlayments generally outperform traditional felt in tear resistance, puncture resistance, and UV stability. They maintain elasticity in cold weather and often handle foot traffic better during installation. For roofs with variable conditions, synthetic products can provide a longer service life and a more consistent performance under UV exposure and weathering. However, the higher initial cost should be weighed against the expected lifespan and warranty terms of the roof system.
In terms of moisture control, all underlayments serve as a secondary line of defense. The critical factor is proper installation: clean deck surfaces, correct laps, and adherence to manufacturer guidelines. Roofs that experience frequent hail, standing water, or heavy ice formation benefit from higher-grade underlayments or additional membranes (like ice-and-water shields) in key locations.
Climate And Regional Considerations
Regional climate strongly influences underlayment choice. In cold, wet, or windy climates, higher-strength felts or synthetic underlayments provide extra protection against moisture intrusion and wind uplift. Regions with heavy snowfall often require better protection against ice damming, making ice-and-water shields near eaves and penetrations especially important. Arid areas with high sun exposure may benefit from UV-stable synthetic underlayments for longer life. Builders should consult local building codes and manufacturers’ recommendations to ensure compatibility with shingles used in their region.
Geography also drives installation practices. Coastal areas with salt air, high humidity, or hurricane exposure demand robust underlayment solutions and proper sealing at joints. Inland regions with extreme temperature swings require membranes that resist thermal expansion and contraction. In hot climates, the underlayment’s temperature resistance affects ease of installation and long-term performance. A well-chosen underlayment contributes to roof longevity and can influence warranty terms for the entire roof system.
Installation Tips And Best Practices
Begin with a clean, dry, and smooth deck. Remove all debris and ensure the surface is free of protrusions that could damage the underlayment. When choosing between felt and tar paper, follow the manufacturer’s installation guidelines exactly. If applying felt, ensure the rolls run perpendicular to the roof slope, with laps aligned to shed water away from joints. Fasteners should be placed according to product instructions to prevent leaks at nail heads.
For felt, traditional practice includes overlapping courses and securing with roofing nails, while ensuring the top edges align to form continuous coverage. If using synthetic underlayment, the installation may allow for lighter fasteners or adhesive methods, depending on the product. In all cases, maintain proper edge and seam sealing, especially around valleys, dormers, and chimney penetrations. Consider a secondary layer like an ice-and-water shield in vulnerable zones for added protection.
Safety is essential. Use fall protection when working on pitched roofs and follow all OSHA guidelines. Weather conditions matter: avoid installing underlayment in wet, windy, or freezing conditions, which can compromise adhesion and edging. Store rolls away from direct sunlight and dispose of damaged materials promptly. Maintain clear access to roof drains and ensure proper ventilation to minimize condensation beneath the underlayment before shingles are installed.
Code And Warranty Considerations
Building codes in the United States specify underlayment requirements that vary by region and climate zone. Some jurisdictions require a specific type of underlayment or minimum shear strength, while others reference the shingle manufacturer’s recommendations. Always verify with local building departments before purchasing underlayment. Roofing warranties often hinge on using approved materials and following installation guidelines, including underlayment type, laps, and fastening patterns. Using an unapproved felt or an incompatible synthetic product can void manufacturer warranties.
Shingle warranties frequently require underlayment compatibility with the chosen shingles. For example, certain laminated asphalt shingles may demand synthetic underlayment for optimal performance. In areas with heavy rainfall or hail, higher-grade underlayments or reinforced felt can be recommended to maintain warranty terms. Homeowners should obtain written confirmation from contractors that the selected underlayment meets code and warranty requirements before work begins.
Choosing Between Roofing Felt And Tar Paper For Your Roof
Deciding between roofing felt and tar paper largely comes down to climate, budget, and local code requirements. For many projects, standard 15-lb or 30-lb asphalt-saturated felt will provide dependable performance at a modest cost. In harsher climates or for roofs with long expected lifespans, synthetic underlayments offer durability, lighter weight, and easier handling, justifying higher upfront costs. Tar paper, while still encountered in some markets, should be viewed as an aging or regional label for asphalt-saturated felts rather than a separate product class.
Consider these criteria when choosing underlayment:
- Climate: Cold and wet regions favor higher-strength felts or synthetics; hot, sunny regions benefit from UV-stable variants.
- Roof Type: Steep slopes, complex roof lines, or areas with high wind require stronger underlayments and possibly ice barriers.
- Shingle Compatibility: Verify that the underlayment is compatible with the shingles chosen for maximum warranty coverage.
- Budget: Felt is typically cheaper; synthetics cost more but last longer and may reduce labor challenges during installation.
- Local Codes: Some jurisdictions mandate synthetic or reinforced underlayment in specific zones or weather conditions.
In practice, many American homeowners opt for synthetic underlayment in new homes or reroofs, especially in areas prone to severe weather. In milder climates or budget-conscious projects, high-quality asphalt-saturated felt remains a viable option when installed correctly. Always defer to the roof manufacturer’s recommendations and local building codes to ensure compliance and maximize warranty protection.
Cost Considerations And Availability
Cost varies by product type, weight, and brand. Roofing felt tends to be among the most economical underlayment options, with 15-lb and 30-lb variants priced accordingly. Tar paper, as a traditional label, often mirrors felt pricing because it is essentially the same base material with different branding in certain markets. Synthetic underlayment typically commands a higher price per square but offers superior durability, lighter weight, and easier handling in some installations.
Availability correlates with regional demand and supplier inventory. Urban and suburban markets with active roofing trades are more likely to carry a broad range of felt and synthetic underlayments. Rural suppliers may stock primarily traditional felt products. When planning a roof project, factor in delivery time, compatibility with shingles, and warranty requirements. It is advisable to obtain multiple quotes and confirm which underlayment products are approved by the shingle manufacturer and local code authorities.
Maintenance, Inspection, And Replacement
Underlayment typically lasts as long as the roof itself if the final roofing material remains intact and the deck is dry. If shingles are replaced later, underlayment may need inspection and potential replacement, especially if damage or aging is evident. Signs of deterioration include curling, gaps at seams, tearing, or bulging in areas subjected to water pooling. In such cases, a professional assessment can determine whether the underlayment should be refreshed during roof replacement or if only the shingles require replacement.
Routine inspections should occur after major storms and seasonal transitions. Look for exposed deck, soft spots, or visible substrate damage from moisture. If the underlayment appears worn or compromised, schedule repairs before installing new shingles. Proper ventilation and roof drainage play a crucial role in extending underlayment life by reducing moisture buildup and temperature fluctuations inside the attic space.
Frequently Asked Questions
Q: Is roofing felt the same as tar paper? A: In modern practice, roofing felt is the general term for asphalt-saturated underlayment, while tar paper is a historic or regional label often used interchangeably. Both refer to asphalt-saturated felts used as roof underlayment, with differences mainly in branding and sometimes thickness.
Q: Do I need underlayment under metal roofing? A: Yes. Even with metal roofing, an underlayment layer is typically required to provide moisture resistance and a continuous surface for fasteners. The choice of underlayment depends on metal type, local codes, and manufacturer guidelines.
Q: Should I use synthetic underlayment or felt? A: Synthetic underlayment offers higher tear resistance, UV stability, and easier installation in many climates. Felt can be adequate on budget projects or in regions where it meets code and warranty requirements. Consider climate, roof design, and manufacturer specifications when choosing.
Q: Are there health or environmental concerns with felt vs synthetic? A: Both products are generally considered safe for typical residential use. Synthetic underlayments may be more resistant to tearing and chemical exposure, while felt products can yield more odor during installation. Always follow product safety data sheets and local disposal guidelines for used underlayment.
Q: How long does underlayment typically last? A: Underlayment longevity ranges from 15 to 40 years depending on material, climate, and roof age. Synthetic underlayments often provide the longest service life, while felt may approach the lower end in harsher climates or when exposed to prolonged sun exposure before shingle installation.
Q: Can tar paper be used on a new roof? A: Yes, in some regions and when approved by the shingle manufacturer and local code. However, most modern installations favor asphalt-saturated felt or synthetic underlayment for improved durability and warranty compatibility.